Pemeliharaan CT(Current Transformer) sebagai Konversi Arus pada Gardu Induk Rangkas Kota 70 KV

Authors

  • Minhaz Tolibin Universitas Sultan Ageng Tirtayasa
  • Mohammad Fatkhurrokhman Universitas Sultan Ageng Tirtayasa

DOI:

https://doi.org/10.55606/jtmei.v4i1.4871

Keywords:

Current Transformer (CT), Maintenance, PT. PLN (Persero) ULTG Rangkasbitung

Abstract

The Substation is a sub-system or a unit of the electric power distribution (transmission) system. Distribution (transmission) is a sub-system of the electric power system. This means that the substation is a sub-sub-system of the electric power system. Therefore, one of the most important equipment in the substation is the current transformer (CT) which is a very important equipment in the substation, where this device is used to convert a large current value into a smaller current value for measurement and protection purposes. The Current Transformer must be in good condition in order to be able to transform the current accurately and thoroughly. The research method carried out in the form of literature studies is to find and collect various references from books and journals as well as previous research related to the research title that the author took, in addition to that the author takes and collects related data needed in the form of CT maintenance data at PT. PLN (Persero) ULTG Rangkasbitung then analyzed all the data that had been collected. The measurement of isolation resistance is carried out at the beginning of the test intended to find out the isolation conditions of the current transformer at an early stage and to avoid subsequent test failures. The test results of the isolation resistance of primary-ground CT in phase R are 130000 MΩ, which means that the CT is still in good condition. Meanwhile, the delta tan test on CT with R phase is 0.17%, which means that the ct is also still in good condition.

Downloads

Download data is not yet available.

References

Agus, S. (2015). Pemakaian dan Pemeliharaan Transformer Arus (Current Transformer/CT) . Jurnal Forum Teknologo Vol.05 No.1.

Anisa, S. (2021). Analisis Setting Relay Difforensial Tipe NR (671, Transormer Daya ^) MV 150 KV di Gardu Induk Mabar. Jurnal Panca Budi Vol.2 No.1.

Efendi, T. H. (2021). Perancangan Alat Monitoring Error Current Transformer (Amor CT) Menggunakan Arduino Mega 1560 dan cayane Iot. Jurnal Teknik Elektro Indonesia Vol.2 No.2.

Hajar, R. &. (2017). Kajian Pemasangan Lightning Arrester Pada Sisi HV transformer Daya Unit Satu Gardu Induk Telak Bitung. Jurnal Ilmiah Energi dan Kelistrikan Vol.9 No.2.

Hestikeh Eirene, P. &. (2019). Energi dan Operasi Tenaga Listrik Dengan Aplikasi ETAP. Yogyakarta: Deepublish.

kurniawan, S. (2020). Analisis Pemeliharaan Trafo Arus Pada Mesin Microline di PT Nayati Indonesia. Jurnal Teknik Elektro Vol.1 No.1.

Lutfi Parinduri, Y. &. (2017). Pembangunan Gardu Induk 150 KV di Desa Parababa Dolok Kecamatan Pangururuan Kabupaten Samosir. Journal Of Elektrical Tecnology Vol.2 No.2.

Margianto, R. (2016). Pengujian Transformator Arus 150 KV Untuk Sistem Proteksi Transformator Tenaga 3 Gardu Induk Purworejo. Jurnal Elektrikal Volume 3 No.1.

Marsudi, D. (2005). Pembangkit Energi Listrik. Jakarta: Erlangga.

Moranin Mungkin, H. S. (2020). Pengujian Keandalan Sistem Current Transformer Dalam Menanggulangi Penggunaan Energi Listrik Secara Ilegel. Jurnal Ecotipe (Electronic, Control, Telecomunication, Information, and Fower Engineering) 7 (2).

Neal, H. (2013). Sistem Subsatition Battery and Baterray. Charger:EPP.

PLN, P. (2009). Pengoprasian Peralatan Gardu Induk. Jakarta: PT PLN (Persero) Pusat Pendidikan dan Pelatihan .

PLN, P. (2014). Buku Pedoman Pemeliharaan Current Transformer (CT) Trafo Arus Surat Keputusan Direksi No 05-0. Jakarta: PT PLN (Persero).

Samuel Marco, G. &. (2013). Analisis Perancangan Gardu Induk Sistem Outdor 150 KV di Talasa Kabupaten Talakar Sulawesi Selatan. Jurnal Dimensi Teknik Elektro Vol.1 No.1.

Wibowo, S. S. (2018). Analisis Sistem tenaga. Malang: Polinema PRESS.

Widianto, A. (2016). Evaluasi Dan Perencanaan Sistem Informasi Pemeliharaan Sarana dan Prasarana di Fakultas Ilmu Komputer Universitas Brawijaya. Jurnal Komputer Ilmiah Administrasi Publik Vol.2 No.3.

Yusniati, N. (2019). Analisis Kerja Circuit Breaker Pada Sisi 150 KV GArdu induk Lamhotma. Jurnal Semnastek Universitas Muhamadiyah Sumatera Vo.1 No.1.

Downloads

Published

2025-02-24

How to Cite

Minhaz Tolibin, & Mohammad Fatkhurrokhman. (2025). Pemeliharaan CT(Current Transformer) sebagai Konversi Arus pada Gardu Induk Rangkas Kota 70 KV. Jurnal Teknik Mesin, Industri, Elektro Dan Informatika, 4(1), 332–342. https://doi.org/10.55606/jtmei.v4i1.4871