Proses Produksi Polymer Sebagai Proteksi Sistem Jaringan Distribusi Tegangan Menengah di PT. Powerindo Prima Perkasa

Authors

  • Marcel Ade Satria Universitas Sultan Ageng Tirtayasa
  • Mustofa Abi Hamid Universitas Sultan Ageng Tirtayasa

DOI:

https://doi.org/10.55606/jtmei.v4i1.4757

Keywords:

Medium voltage distribution network, electrical system protection, consumer safety

Abstract

The medium voltage distribution network system is an integral part of the process of transmitting electrical energy from the substation to consumers. This transfer aims to supply electricity for daily use by consumers and can also be applied in industrial environments. The importance of electricity in modern development makes it a critical element; if a power outage occurs, our activities will be disrupted. Therefore, protection is needed within the medium voltage distribution network system to safeguard against damage to the network infrastructure, which could lead to power outages. To reduce the occurrence of such issues, protective components have been developed to protect the medium voltage distribution network facilities, ensuring the safety of consumers from the 24kV medium voltage distribution system, which could be fatal in case of direct contact.

Downloads

Download data is not yet available.

References

Arya, Kurniawan,dkk. (2020). Analisa perbandingan pemakaian Fuse Cut Out (FCO)Dan tidak memakai Fuse Cut Out (FCO) pada Penyalungan Percabangan Rijali terhadap Energy Not Served (ENS). Ambon : Politeknik Negeri Ambon

Buku SPLN D5.006: 2013. Pedoman Pemeliharaan ARRESTER Untuk Jaringan Distribusi 20 kV

Buku SPLN D3.026: 2017. Spesifikasi Fuse Cut Out.

Hartanti, Lestari Nurreta. 2018. Analisis Kondisi Pembangkit Hubung Bagi Tegangan Rendah (PHB-TR) Gardu Distribusi Wilayah Cilegon. Jakarta : Universitas Negeri Jakarta

Paemboyan, Evan Januar,dkk. (2021). Analisis Fuse Cut Out sebagai Proteksi Penyulang Tondon pada Jaringan Distribusi di PT.PLN (Persero) ULP Rantepao. Sulawesi Selatan : Politeknik Ujung Pandang

Rochman, Arif Noor. 2019. Analisis Ketidak Seimbangan Beban Terhadap Arus Netral Pada Transformator Utama 1250 kVA Universitas Semarang. Universitas Semarang

Sulistyanto, Dwi Aji,dkk. (2012). Analisa Arus Bocor dan Tegangan Flashover pada Isolator Suspension 20 kV 3 Sirip dengan 4 Tipe Sirip Berbahan Polimer Resin Epoxy Silane Silica. Semarang: Universitas Diponegoro Semarang

Scrapetrra.International Labour Organization. (2015). International Labour Conference: Labour protection in a transforming world of work. Retrieved from www.ilo.org/publns.

Scrapetrra.International Labour Organization. (2021, september 17). WHO/ILO: Almost 2 million people die from work-related causes each year. Retrieved from and health: Occupational safety https://www.ilo.org/global/about-the ilo/newsroom/news/WCMS_819705/lang--en/index.htm

Scrapetrra.International Trade Union Confederation. (2020. juni 18). 2020 ITUC Global Rights Index: violations of workers' rights at seven-year high. Retrieved from ituc-csi.org: https://www.ituc-csi.org/violations workers-rights-seven-year-high

Downloads

Published

2025-01-20

How to Cite

Marcel Ade Satria, & Mustofa Abi Hamid. (2025). Proses Produksi Polymer Sebagai Proteksi Sistem Jaringan Distribusi Tegangan Menengah di PT. Powerindo Prima Perkasa. Jurnal Teknik Mesin, Industri, Elektro Dan Informatika, 4(1), 68–93. https://doi.org/10.55606/jtmei.v4i1.4757