Penggunaan Kontaktor pada Sistem Pengaman Motor Induksi 3 Phasa

Authors

  • Kalika Khaldan Nurshofa Universitas Sultan Ageng Tirtayasa
  • Aldi Fadillah Ramadan Universitas Sultan Ageng Tirtayasa
  • Nur Fajri Faiz Universitas Sultan Ageng Tirtayasa
  • Paul Manurung Universitas Sultan Ageng Tirtayasa
  • Diajeng Luluk Karlina Universitas Sultan Ageng Tirtayasa

DOI:

https://doi.org/10.55606/jtmei.v3i4.4567

Keywords:

contactor, Safety, System, Induction

Abstract

Three-phase induction motors are electric motors that are widely used in the industry due to their reliability and efficiency. However, these motors are prone to disturbances such as unstable voltages, overloads, and short circuits, which can cause serious damage. To protect the motor, a reliable safety system is required. This article discusses the role of magnetic contactors in the safety system of three-phase induction motors, including their working principles, types of contactors, and their application to protect motors from electrical interference. The contactor functions as an electromagnetic switch that can connect and disconnect electricity automatically, improving operator safety by enabling remote operation. In addition, this safety system is equipped with sensors that monitor electrical parameters, allowing for a quick response to disturbances. Thus, the use of contactors in the safety system of three-phase induction motors is essential to maintain reliability and safety.

Downloads

Download data is not yet available.

References

Elbani, A. (2011). Implementasi pengendali PLC pada sistem motor tiga phasa untuk star Y/?. ELKHA: Jurnal Teknik Elektro, 3(1).

Juwono, C. P., Joko, J., Suprianto, B., & Endryansyah, E. (2022). Simulasi sistem proteksi motor induksi tiga fasa terhadap gangguan menggunakan programmable logic controller (PLC) Omron CP1H berbasis Cx-Programmer 9.6. Jurnal Teknik Elektro, 11(3), 409-415.

Naufal, M. I., & Irwanto, I. (2023). Motor listrik 3 fasa sebagai sistem penggerak motor roll pada mesin case sealer di PT. Matahari Megah. Jurnal Sains dan Teknologi, 2(1), 32-45.

Silva, S. M., Braga, M. F., de Fernandes, T., & Milagres, L. (2007). Analysis and development of a ride-through device for AC contactors. 2007 European Conference on Power Electronics and Applications. https://doi.org/10.1109/epe.2007.4417762

Sudiarta, I. P., Wijaya Arta, I. W., & Raka Agung, I. G. A. P. (2015). Rancang bangun pengaman motor induksi 3 fasa terhadap unbalance voltage dan overload dengan sistem monitoring. E-Journal SPEKTRUM, 2(1), 13-18.

Downloads

Published

2024-11-30

How to Cite

Kalika Khaldan Nurshofa, Aldi Fadillah Ramadan, Nur Fajri Faiz, Paul Manurung, & Diajeng Luluk Karlina. (2024). Penggunaan Kontaktor pada Sistem Pengaman Motor Induksi 3 Phasa. Jurnal Teknik Mesin, Industri, Elektro Dan Informatika, 3(4), 280–289. https://doi.org/10.55606/jtmei.v3i4.4567