Penatalaksanaan Pemeriksaan CT-Scan Cardiac Dengan Modifikasi Tatalaksana Pada Kasus Heart Rate Tinggi Di Rumah Sakit Primaya Tangerang

Authors

  • Amraini Amraini AKTEK Radiodiagnostik dan Radioterapi Bali
  • Edwien Setiawan Departemen Radiologi Rumah Sakit Primaya Tangerang

DOI:

https://doi.org/10.55606/termometer.v2i1.2799

Keywords:

Cardiac CT, Heart Rate, Software Modification

Abstract

Cardiac CT-Scan is a series of examinations to produce cardiac imaging aimed at identifying fatty deposits or calcium in the coronary arteries, so that a better treatment can be determined for the patient. Heart rate is the number of heartbeats per unit time, usually expressed in minutes / beats per minute (bpm) which is based on the number of ventricular contractions. Cardiac CT Scan examination with high heart rate can be modified using GE Revolution Maxima CT-Scan software using SnapShot Freeze Technology with extended cardiac helical pitch scanning mode which provides a significant dose reduction for higher heart rate scans. CT Scan Cardiac begins with patient preparation, tools and materials, patient positioning and examination protocols as well as the reconstruction process. This study used a qualitative research method with a case study approach using one patient.

References

Hutami IAPA, Sutapa GN, Paramarta IBA. Analisis Pengaruh Slice Thickness Terhadap Kualitas Citra Pesawat CT Scan Di RSUD Bali Mandara. Bul Fis. 2021;22(2):77.

Pramitya N, Darmini P, Dwi B.Penerapan Slice Thickness Pada Pemeriksaan Ct Scan Kepala Dengan Kasus Traumatic Brain Injury ( Literature Review ). 2019;1–7.

Edith J . Applegate P. The Sectional Anatomy Learning System. Westline Industrial Drive St. Louis Missouri 63146. 2010. 146–148 p.

D K, Deepa C. Step by Step CT Scan (A Practical Guide for Residents and Technologists). Vol. 28, JAYPEE BROTHERS MEDICAL PUBLISHERS (P) LTD. New Delhi; 2005. 362–366 p.

Utami AD, Kartikasari Y, Wijokongko S. prosedur pemeriksaan CT Cardiac dengan Kasus Coronary Artery By Pass Grafting (CABG) di Instalasi Radiologi MRCCC SILOAM Hospital Semanggi. J Imejing Diagnostik. 2017;3(2):248–54.

BABIKER DEI. Arduino based heart rate monitoring and heart attack detection system. Heal Technol biometrics [Internet]. 2017;1(124046):241. Available from: http://khartoumspace.uofk.edu/b itstream/handle/123456789/2582 4/DUAA124046.pdf?sequence=1& is Allowed=y

Dutta S. Cardiac CT Advancement – Evolution of SnapShot Freeze Technology SnapShot Freeze Technology : A primer.

Sukatin, Nurkhalipah, Kurnia A, Ramadani D, Fatimah. Humantech Jurnal Ilmiah Multi Disiplin Indonesia. J Ilm Multi Disiplin Indones. 2022;1(9):1278–85.

Downloads

Published

2023-10-31

How to Cite

Amraini Amraini, & Edwien Setiawan. (2023). Penatalaksanaan Pemeriksaan CT-Scan Cardiac Dengan Modifikasi Tatalaksana Pada Kasus Heart Rate Tinggi Di Rumah Sakit Primaya Tangerang. Termometer: Jurnal Ilmiah Ilmu Kesehatan Dan Kedokteran, 2(1), 66–71. https://doi.org/10.55606/termometer.v2i1.2799