Pemeliharaan Pentanahan Pada Tower Transmisi Milik PT PLN Persero ULTG Cikupa

Authors

  • Rahima Mahabbah Universitas Sultan Ageng Tirtayasa
  • Endi Permata Universitas Sultan Ageng Tirtayasa
  • Legista Romadhoni Mardillah PT PLN (Persero) ULTG Cikupa

DOI:

https://doi.org/10.55606/juprit.v2i4.3082

Keywords:

Grounding System, Tower, Ground Steel Wire, Maintenance

Abstract

Transmission lines are a medium used to transmit electrical energy from generators to consumers who use electricity. One of the components for delivering electric power is the SUTT and SUTET towers. This air duct tower uses a grounding system to protect the tower from external and internal disturbances. One of the disturbances is lightning strikes whose resistance is very large, if a grounding system is not installed it will damage tower components or equipment. The grounding system works to channel the voltage from lightning directly to the earth. The grounding system needs regular maintenance because it is very important to protect the components on the tower in the event of a lightning strike. The maintenance carried out is by measuring the grounding resistance value according to PT PLN standard rules, namely 70 kV transmission network towers are less than or equal to 5 ohms, for 150 kV it is less than or equal to 10 ohms and for 500 kV it is less than or equal to 15 ohm. And maintenance uses drones to see the condition of the GSW (Ground Steel Wire) cable from a height.

References

I. S. , W. I. A. , & J. I. Wicaksana, “ANALISIS SISTEM PEMBUMIAN TOWER SALURAN TRANSMISI DARI GARDU INDUK KAPAL - GARDU INDUK BIANYAR.,” SPEKTRUM, 57., 2021.

PT PLN (PERSERO). (Jakarta)., Buku Pedoman Pemeliharaan Saluran Udara Tegangan Tinggi dan Ekstra Tinggi (SUTT/SUTET). . 2014.

G. , & F. D. Tamahullah, “Analisis Tahanan Pentanahan pada Kaki Tower SUTT 150kV Jatiluhur- Padalarang Institut Teknologi Nasional. ,” SNETO, 346., 2021.

A. , A. M. , H. J. , & H. U. Faisal, “Studi Pengukuran Tahanan Pentanahan Menara Saluran Udara Tegangan Tinggi (SUTT) 150 kV Sidikalang - Salak Denagan Menggunakan Sistem Counterpoise.,” ISSN, 130., 2019.

A. A. , & S. N. Abdullah, “Analisis Sistem Pentanahan Tower Transmisi Saluran Udara Tegangan Tinggi Penghantar150kV Kamojang - Darajat dan Modifikasi Perbaikan Resistansi Pentanahan Menggunakan Metode Driven Ground. ,” Universitas Gadjah Mada, 12., 2019.

M. , P. D. D. , & R. A. Sofyan, “PRILAKU STRUKTUR TOWER TRANSMISI TIPE SUSPENSION TERHADAP BEBAN ANGIN.,” Forum Mekanika, 13., 2018.

K. K. R.I., “Memasang Sistem Pembumian. ,” Jakarta Selatan: KTL.IK02.108.01., 2018.

R. P. , P. L. S. , & M. G. M. Luntungan, “Analisa Daerah Lindung dan Grounding Pada Tower Transmisi Akibat Terjadinya Back Flashover. ,” Teknik Elektro dan Komputer, 199., 2018.

Downloads

Published

2023-10-08

How to Cite

Rahima Mahabbah, Endi Permata, & Legista Romadhoni Mardillah. (2023). Pemeliharaan Pentanahan Pada Tower Transmisi Milik PT PLN Persero ULTG Cikupa. Jurnal Penelitian Rumpun Ilmu Teknik, 2(4), 165–173. https://doi.org/10.55606/juprit.v2i4.3082